引用本文:邓达治,黄向红.重症患者深静脉穿刺置管术后管腔内血栓的彩色多普勒超声检查监测应用研究[J].中国临床新医学,2012,5(8):725-727.
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 1444次   下载 1242 本文二维码信息
码上扫一扫!
分享到: 微信 更多
重症患者深静脉穿刺置管术后管腔内血栓的彩色多普勒超声检查监测应用研究
邓达治,黄向红
530021 南宁,广西壮族自治区人民医院急诊科
摘要:
[摘要] 目的 评价彩色多普勒超声检查对监测重症患者深静脉穿刺置管前后管腔内血栓形成的价值。方法 选取在急诊重症监护室(EICU)住院凝血功能正常的深静脉穿刺置管患者7例,术前抽血测定C反应蛋白(CRP)、D-二聚体(D-Dimer)、血小板计数(PLT)、凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)、血浆纤维蛋白原(FIB)、凝血酶时间(TT)。置管>48 h者在抽血复查CRP、D-Dimer、PLT、PT、APTT、FIB、TT且病情允许情况下,行B超检查监测深静脉穿刺管内管外是否有血栓形成,并取样送病理检查。评价超声检查在监测深静脉穿刺置管术后管腔内血栓的价值。结果 7例患者静脉穿刺置管前后各项指标比较差异无统计学意义(P>0.05)。6例超声检查见导管内血栓形成,经病理检查支持B超诊断。结论 彩色多普勒超声检查对监测深静脉导管内血栓形成有较好的价值。
关键词:  彩色多普勒超声  导管内血栓  深静脉穿刺
DOI:10.3969/j.issn.1674-3806.2012.08.10
分类号:R 445
基金项目:广西卫生厅科研课题(编号:Z2010254)
Application research on color Doppler flow imaging in monitoring the occurrence of intraductal thrombosis after deep venous catheterization in severe patients
DENG Da-zhi,HUANG Xiang-hong
Department of Emergency,the People′s Hospital of Guangxi Zhuang Autonomous Region,Nanning 530021,China
Abstract:
[Abstract] Objective To investigate the effect of color Doppler flow imaging in monitoring the occurrence of intraductal thrombosis after deep venous catheterization in severe patients.Methods Seven seriously ill patients with normal coagulantion function in EICU of the people′s hospital of Guangxi Zhuang Autonomous Region were chosen. CRP,D-D,PLT,PT,APTT,FIB and TT of patients were tested before deep venous puncture. 48 hours later,The aforementioned items were tested again and the deep venous catheters were monitored by colour Doppler flow imaging. Successionally the deep venous catheters were pulled out and the intraductal thrombosis were tested by pathological examination. All the test results and the relevant factors of intraductal thrombosis after deep venous catheter was inserted were statistically analysed.Results The intraductal thrombosis in 7 patients were verified through pathological examination after deep venous catheter were inserted. The statistical difference of the test result of CRP,D-D,PLT,PT,APTT,FIB,TT were not significant before and after deep venous venipuncture (P> 0.05).yet,the intraductal thrombosis in 6 patients could be monitored by color Doppler flow imaging.Conclusion It is a good means to use Doppler flow imaging to monitor the occurrence of intraductal thrombosis in deep venous catheterization.
Key words:  Color Doppler flow imaging  Intraductal thrombosis  Deep venous puncture